{"id":2029,"date":"2018-06-28T14:05:16","date_gmt":"2018-06-28T14:05:16","guid":{"rendered":"http:\/\/yourtemporaryurl.com\/linsley\/?page_id=2029"},"modified":"2018-07-05T19:24:52","modified_gmt":"2018-07-05T19:24:52","slug":"landfill-monitoring","status":"publish","type":"page","link":"https:\/\/yourtemporaryurl.com\/linsley\/landfill-monitoring\/","title":{"rendered":"Landfill monitoring"},"content":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1530201366522{margin-top: 40px !important;}&#8221;][vc_column][vc_text_separator title=&#8221;Landfill Monitoring&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2183&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1530647209469{margin-bottom: 40px !important;}&#8221;]<\/p>\n<p style=\"text-align: center;\"><strong>Applications<\/strong><\/p>\n<p>The Control Analytics, Inc. Model AB-100 is designed to monitor oxygen (O<sub>2<\/sub>), methane (CH<sub>4<\/sub>) and\/or carbon dioxide (CO<sub>2<\/sub>) in recovered gases from landfill and bio-gas operations. The system employs state-of-the-art IR Technology for methane and CO<sub>2<\/sub>\u00a0analysis and includes options for long life electrochemical O<sub>2<\/sub>\u00a0or more robust non-depleting paramagnetic O<sub>2<\/sub>\u00a0detectors.<\/p>\n<p>This system includes fast response and a robust sample system, including continuous moisture removal without the need for thermoelectric coolers. The dual stage moisture removal employs both compression and permeation drying for handling samples with moistures up to a predetermined amount by volume. A high moisture option is available for moisture contents to 30% by volume.<\/p>\n<p>The standard system includes auto calibration, which is programmable by the user on the instrument LCD display panel. An option can be purchased to provide internal span calibrations, ensuring that the only calibration gas needed to operate the system is compressed nitrogen.<\/p>\n<p>Also included is an optional H<sub>2<\/sub>S filter for use in high H<sub>2<\/sub>S applications.<\/p>\n<p>The system is supplied for use in general purpose electrical classifications or can be purchased in a Class 1 Division 2 Groups B-C-D configuration without the need for a Z purge system. This eliminates the need for compressed air in these applications.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]<a class=\"readmore\" style=\"width: 250px; display: block; margin: 20px 30px 20px 30px; text-align: center; horizontal-align: center;\" href=\"https:\/\/controlanalytics.com\/wp-content\/uploads\/2011\/06\/Landfill-and-Biogas-Monitoring-System-1.pdf\" target=\"blank\">READ MORE<\/a>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][\/vc_column_inner][\/vc_row_inner][vc_separator css=&#8221;.vc_custom_1530201946421{margin-top: 40px !important;}&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<p style=\"text-align: center;\">Call us at <strong>1-800-240-8619<\/strong> or email us at\u00a0<strong><a href=\"mailto:sales@controlanalytics.com\" target=\"_blank\" rel=\"noopener\">sales@controlanalytics.com<\/a><\/strong><\/p>\n<p style=\"text-align: center;\">to find out more about our line of Landfill Monitoring Systems.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row css=&#8221;.vc_custom_1530201366522{margin-top: 40px !important;}&#8221;][vc_column][vc_text_separator title=&#8221;Landfill Monitoring&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;2183&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1530647209469{margin-bottom: 40px !important;}&#8221;] Applications The Control Analytics, Inc. Model AB-100 is designed to monitor oxygen (O2), methane (CH4) and\/or carbon dioxide (CO2) in recovered gases from landfill and bio-gas operations. The system employs state-of-the-art IR Technology for methane and CO2\u00a0analysis and includes options for long [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":"","_wp_rev_ctl_limit":""},"class_list":{"0":"post-2029","1":"page","2":"type-page","3":"status-publish","5":"entry","6":"has-post-thumbnail","7":"override"},"_links":{"self":[{"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/pages\/2029","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/comments?post=2029"}],"version-history":[{"count":18,"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/pages\/2029\/revisions"}],"predecessor-version":[{"id":2553,"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/pages\/2029\/revisions\/2553"}],"wp:attachment":[{"href":"https:\/\/yourtemporaryurl.com\/linsley\/wp-json\/wp\/v2\/media?parent=2029"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}